Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Vaccine: X ; 2023.
Artículo en Inglés | EuropePMC | ID: covidwho-2275147

RESUMEN

The IgG antibody titer against SARS-CoV-2 receptor binding protein (RBD) after mRNA vaccine were compared between those with and without previous infection (PI) for up to 48 weeks. Though sustained higher IgG-RBD were observed in the PI group after two doses of vaccines, both groups benefited from the booster shots of the third vaccine. This data supports the necessity of the booster shots to those with PI.

2.
Vaccine X ; 13: 100282, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: covidwho-2275148

RESUMEN

The IgG antibody titer against SARS-CoV-2 receptor binding protein (RBD) after mRNA vaccine were compared between those with and without previous infection (PI) for up to 48 weeks. Though sustained higher IgG-RBD were observed in the PI group after two doses of vaccines, both groups benefited from the booster shots of the third vaccine. This data supports the necessity of the booster shots to those with PI.

4.
Virol J ; 19(1): 188, 2022 11 16.
Artículo en Inglés | MEDLINE | ID: covidwho-2117139

RESUMEN

INTRODUCTION: We investigated the performance of the cobas® 6800 system and cobas SARS-CoV-2 & Influenza A/B, a fully automated molecular testing system for influenza viruses and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). This enabled an assay in a batch of 96 samples in approximately 3 h. METHODS: An assay was performed using the cobas SARS-CoV-2 & Influenza A/B on the cobas 6800 system for samples collected in four facilities between November 2019 and March 2020 in our previous study. The results were compared with those obtained using the reference methods. RESULTS: Of the 127 samples analyzed, the cobas SARS-CoV-2 & Influenza A/B detected influenza A virus in 75 samples, of which 73 were positive using the reference methods. No false negative results were observed. The overall positive and negative percent agreement for influenza A virus detection were 100.0% and 96.3%, respectively. There were no positive results for the influenza B virus or SARS-CoV-2. CONCLUSION: The cobas 6800 system and cobas SARS-CoV-2 & Influenza A/B showed high accuracy for influenza A virus detection and can be useful for clinical laboratories, especially those that routinely assay many samples.


Asunto(s)
COVID-19 , Gripe Humana , Orthomyxoviridae , Humanos , Gripe Humana/diagnóstico , SARS-CoV-2/genética , Técnicas de Diagnóstico Molecular
5.
PLoS One ; 16(9): e0257452, 2021.
Artículo en Inglés | MEDLINE | ID: covidwho-1440988

RESUMEN

OBJECTIVES: A few studies on antibody testing have focused on asymptomatic or mild coronavirus disease 2019 (COVID-19) patients with low initial anti-severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody responses. Anti-SARS-CoV-2 antibody-testing performance was evaluated using blood samples from asymptomatic or mild COVID-19 patients. METHODS: Blood samples were collected from 143 COVID-19 patients during an outbreak on a cruise ship 3 weeks after diagnosis. Simultaneously, a follow-up SARS-CoV-2 genetic test was performed. Samples stored before the COVID-19 pandemic were also used to evaluate the lateral flow immunochromatographic assay (LFA) and electrochemiluminescence immunoassay (ECLIA). Titers of anti-SARS-CoV-2 IgM and IgG antibodies against the nucleocapsid and spike proteins were measured using the enzyme-linked immunosorbent assay to confirm which antibodies were influenced on LFA- and ECLIA- false-negative result in crew-member samples. RESULTS: Sensitivity, specificity, positive-predictive, and negative-predictive values of LFA-detected IgM antibodies were 0.231, 1.000, 1.000, and 0.613, respectively; those of LFA-detected IgG antibodies were 0.483, 0.989, 0.972, and 0.601, respectively; and those of ECLIA-detected total antibodies were 0.783, 1.000, 1.000, and 0.848, respectively. All antibody titers measured using ELISA were significantly lower in blood samples with negative results than in those with positive results in both LFA and ECLIA. In the patients with negative results from the follow-up genetic testing, IgM-, IgG-, and total-antibody positivity rates were 22.9%, 47.6%, and 72.4%, respectively. CONCLUSIONS: These findings suggest that anti-SARS-CoV-2 antibody testing has lower performance in asymptomatic or mild COVID-19 patients than required in the guidelines.


Asunto(s)
Prueba Serológica para COVID-19/métodos , COVID-19/diagnóstico , COVID-19/inmunología , Adulto , Anticuerpos Antivirales/inmunología , Infecciones Asintomáticas/epidemiología , Prueba Serológica para COVID-19/tendencias , Prueba de COVID-19/métodos , Brotes de Enfermedades/prevención & control , Ensayo de Inmunoadsorción Enzimática/métodos , Femenino , Humanos , Inmunoensayo/métodos , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , SARS-CoV-2/inmunología , Sensibilidad y Especificidad , Navíos
6.
PLoS One ; 16(6): e0252964, 2021.
Artículo en Inglés | MEDLINE | ID: covidwho-1264222

RESUMEN

OBJECTIVES: The accurate detection of severe acute respiratory syndrome-coronavirus 2 (SARS-CoV-2) is essential for the diagnosis of coronavirus disease 2019 (COVID-19). We compared the quantitative RT-PCR results between nasopharyngeal swabs and saliva specimens. METHODS: A COVID-19 outbreak occurred on a cruise ship at Nagasaki port, Japan. We obtained 123 nasopharyngeal swabs and saliva each from asymptomatic or mild patients in the late phase of infection. RESULTS: The intervals from the diagnosis to the sampling were 25.5 days for nasopharyngeal swabs and 28.9 days for saliva. The positive rate was 19.5% (24/123) for nasopharyngeal swabs and 38.2% (47/123) for saliva (P = 0.48). The quantified viral copies (mean ± SEM copies/5 µl) were 9.3±2.6 in nasopharyngeal swabs and 920±850 in saliva (P = 0.0006). CONCLUSIONS: The advantages of saliva specimens include positive rate improvement and accurate viral load detection. Saliva may be used as a reliable sample for SARS-CoV-2 detection.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19 , COVID-19/diagnóstico , Nasofaringe/virología , SARS-CoV-2/aislamiento & purificación , Saliva/virología , Humanos , Manejo de Especímenes
7.
J Infect Chemother ; 27(6): 820-825, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: covidwho-1045151

RESUMEN

INTRODUCTION: Digital immunoassays (DIAs) and molecular point-of-care (POC) tests for influenza were recently developed. We aimed to evaluate and compare the positive rate with molecular POC tests and DIAs in detecting influenza virus A, B and respiratory syncytial virus (RSV). METHODS: A prospective observational study was conducted in 2019-2020. Nasopharyngeal swab samples were collected from adult outpatients with influenza-like illness who visited four hospitals and clinics in Japan. DIAs were performed at each facility. The clinical diagnosis was determined based on the findings of DIAs, history taking, and physical assessment. Molecular POC test and reverse transcription polymerase chain reaction (RT-PCR) were performed later. RESULTS: A total of 182 patients were evaluated. The positive rate for influenza virus with molecular POC test was significantly higher than that with DIAs (51.6% versus 40.7%, p = 0.046). In patients who tested positive for influenza virus with only molecular POC test, the presence of influenza virus was confirmed by RT-PCR. In a comparison between the patients who were positive for influenza virus with only molecular POC test and those with both molecular POC test and DIA, the percentage of patients who sought consultation within 18 h after the onset of symptoms was significantly higher in the molecular POC test only group than in the both methods group (70.0% versus 43.2%, p = 0.044). CONCLUSIONS: A molecular POC test could contribute to the accurate diagnosis of influenza in patients with influenza-like illness, especially those who visited a hospital immediately after the onset of symptoms.


Asunto(s)
Virus de la Influenza A , Gripe Humana , Orthomyxoviridae , Infecciones por Virus Sincitial Respiratorio , Adulto , Humanos , Inmunoensayo , Virus de la Influenza A/genética , Virus de la Influenza B/genética , Gripe Humana/diagnóstico , Japón , Orthomyxoviridae/genética , Sistemas de Atención de Punto , Pruebas en el Punto de Atención , Infecciones por Virus Sincitial Respiratorio/diagnóstico , Sensibilidad y Especificidad
8.
Microbes Infect ; 23(4-5): 104812, 2021.
Artículo en Inglés | MEDLINE | ID: covidwho-1157618

RESUMEN

This retrospective study evaluated stored nasopharyngeal swab samples from Japanese patients with influenza-like illness during the 2019/2020 season. We aimed to determine whether COVID-19 had spread in the community before the first confirmed case. The period of influenza season during 2019/2020 in Nagasaki was shorter than in previous influenza seasons. When the first COVID-19 case was reported in Nagasaki prefecture, the number of influenza cases were very low. No positive results for SARS-CoV-2 were detected in 182 samples that were obtained from adult outpatients. Our results revealed no large-scale spread of COVID-19 in the community before the first confirmed case.


Asunto(s)
COVID-19/diagnóstico , COVID-19/epidemiología , Prueba de Ácido Nucleico para COVID-19 , Humanos , Gripe Humana/epidemiología , Japón/epidemiología , Estudios Retrospectivos , SARS-CoV-2/aislamiento & purificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA